Waterproof rubber sheathed flexible cable

Short Description:

  Application The product is to suitabel for power transmission in underwater motors with AC voltage of 500V.   Product features (1)The c……


Product Detail

 

Application

The product is to suitabel for power transmission in underwater motors with AC voltage of 500V.

 

Product features

(1)The cable wire core allows long time working temperature of 65℃.

(2)The cable has better electric insulation even when soaked in the water or under larger hydraulic pressure and requires that the cover material absorbs little water under hydraulic pressure.

(3)The cable is soft and easy to bend,which is also able to move frequently.

 

Type names and manufacture range

Cores

(mm2)
Number of cores × nominal sectional area of the conductor

Diameter/Number of Roots
(mm)

(mm)
Insulation nominal thickness

(mm)
Jacket nominal thickness

(mm)
Maximum external diameter

(kg/km)
Approximate weight

1-core

1×4

49/0.32

1.2

2.0

9.3

1×6

84/0.30

1.2

2.0

9.9

1×10

84/0.40

1.4

2.0

12.1

1×16

126/0.40

1.4

2.0

13.5

1×25

196/0.40

1.6

2.5

16.5

1×35

276/0.40

1.6

2.5

17.5

1×50

396/0.40

1.6

2.5

19.0

1×70

360/0.50

1.6

2.5

21.4

3-core

3×2.5

49/0.25

1.0

2.0

13.4

382

3×4

56/0.30

1.0

2.0

15.5

386

3×6

84/0.30

1.0

2.0

16.9

485

3×10

84/0.40

1.2

2.5

22.3

850

3×16

126/0.40

1.2

2.5

24.6

1103

3×25

196/0.40

1.4

2.5

31.6

1774

3×35

276/0.40

1.4

2.5

33.8

2164

4-core

3×2.5+1×1.5

49/0.25+30/0.30

1.0+1.0

2.0

15.1

340

3×4+1×2.5

49/0.32+49/0.25

1.0+1.0

2.0

16.5

425

3×6+1×4

84/0.30+56/0.30

1.0+1.0

2.5

18.9

596

3×10+1×6

84/0.40+84/0.30

1.2+1.0

2.5

23.2

943

3×16+1×6

126/0.40+84/0.30

1.2+1.0

2.5

25.3

1180

3×25+1×6

196/0.40+84/0.30

1.4+1.0

2.5

32.4

1890

3×35+1×6

49/0.40+84/0.30

1.4+1.0

2.5

34.4

2268

 

Performance index

 

Industrial frequency pressure of wire cores

Industrial frequency pressure of finished cores

Circuit horizontal
Tightness test

Water absorbing test of rubber under hydraulic pressure

Immensed chamber in warm water for 6h

Immensed in warm water for 6h

(MΩ•km)

(V)
Test voltage

(min)
Pressure time

(min)
Pressure time

(V)
Test voltage

Immensed and pressured insulation resistance at 20℃

2500

5

5

2500

100

On a cylinder with a diameter of 5 times the cable, bend it 10 times and place it in a water tank of 30 atmospheres for 2 hours, and the exposed part of the cable will not leak.

In 30 atmospheres of water at room temperature, the rubber sheath is placed for 24 hours, and the weight increase does not exceed 16mg/cm3

 

 

Leave Your Message