Overhead insulated cables with rated voltage 1KV and below

Short Description:

  Application This product is applicable to aerial power lines of AC rated voltage 1KV and below. This series of aerial weathering insulat……


Product Detail

 

Application

This product is applicable to aerial power lines of AC rated voltage 1KV and below. This series of aerial weathering insulated cable has different types of cores such as copper core,aluminium core and alloy

Aluminium core and different types of insulation such as polyvinly chloride,polythene and cross-linking polythene.

 

Product features

(1) The rated voltage is 0.6/1KV;the permissible long time working temperature of conductor:relative to the PVC insulated and polythene insulated cable,it must be below 70℃, relative to the XLPE insulated and polythene insulated cable,it must be below 90℃;during the cable laying,the ambient temperature must be above -20℃.

(2) The permissible bending radius of cable:if the external diameter of cable is less than 25mm,it must be more than four times of external; if the external diameter of cable is more than 25mm,it must be more than six times of external.

 

Type names and usable range

Type

Name

Usage range

JKV

Aerial polyvinyl chloride insulated copper core cable

 
To be fixedly laid in the air,and to be usable for wires of
the hous service

JKLV

Aerial polyvinyl chloride insulated aluminium core cable

JKLHV

Aerial polyvinyl chloride insulated aluminium alloy core cable

JKY

Aerial polyvinyl insulated copper core cable

To be fixedly laid in the air,and to be usable for wires service

JKLY

Aerial polyvinyl insulated aluminium core cable

JKLHY

Aerial polyvinyl insulated aluminium alloy core cable

JKYJ

Aerial cross-linking polyvinyl insulated copper core cable

 

To be fixedly laid in the air,and to be usable for wires of the hous service

JKLYJ

Aerial cross-linking polyvinyl insulated aluminium core cable

JKLHYJ

Aerial cross-linking polyvinyl insulated aluminium alloy core cable

Manufacture range

Type

Number of cores

(mm2) Nominal cross area

JKV JKLV JKLHV JKY JKLY
JKLHY JKYJ JKLYJ JKLHYJ

1

16-240

2、4

10-120

JKLV JKLY JKLYJ

3+N

10-120

 

(mm2)
Nominal cross area conductor

(mm)
Diameter of conductor

(mm)
   Thickness of insulator

(mm)
Calculated external diameter

(kg/km) Appoximate weight

JKY
JKYJ

JKLY JKLHY
JLYKJ JKLHYJ

JKV

JKLV
JKLHV

10

3.8

1.0

6.5

106

44.3

115.4

53

16

4.8

1.2

8.0

167

68.7

181.3

82

25

6.0

1.2

9.5

253

98.0

269

114

35

7.0

1.4

11.0

352

135

374

158

50

8.3

1.4

12.5

492

182

517

207

70

10.0

1.4

14.0

678

244

708

274

95

11.6

1.6

16.5

917

329

956

368

120

13.0

1.6

18.0

1149

405

1192

448

150

14.6

1.8

20.0

1435

505

1489

559

185

16.2

2.0

22.5

1769

622

1835

688

240

18.4

2.2

25.5

2288

800

2369

881